{"id":1081,"date":"2021-11-09T16:53:38","date_gmt":"2021-11-09T15:53:38","guid":{"rendered":"https:\/\/inspire-polyfoam.de\/?page_id=1081"},"modified":"2026-06-25T15:39:22","modified_gmt":"2026-06-25T13:39:22","slug":"pollex","status":"publish","type":"page","link":"https:\/\/ispt-solutions.com\/en\/pollex\/","title":{"rendered":"Valor PollEx"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"371\" height=\"61\" src=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2026\/06\/083449A5-0085-48D0-AD30-06151634619D.png\" alt=\"\" class=\"wp-image-1625\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2026\/06\/083449A5-0085-48D0-AD30-06151634619D.png 371w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2026\/06\/083449A5-0085-48D0-AD30-06151634619D-300x49.png 300w\" sizes=\"auto, (max-width: 371px) 100vw, 371px\" \/><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"> <br>Valor PollEx is a PCB-level Electronic Design Automation (EDA) software suite covering design review,  <br>analysis and manufacturing. It significantly reduces development cycles while providing a common communication <br>application between schematic engineers, PCB designers, CAE analysts, and manufacturing engineers. <\/p>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"457\" src=\"https:\/\/inspire-polyfoam.de\/wp-content\/uploads\/2021\/11\/Pollex_PCB_01-1024x457.png\" alt=\"\" class=\"wp-image-1083\" style=\"width:265px;height:117px\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_01-1024x457.png 1024w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_01-300x134.png 300w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_01-768x343.png 768w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_01.png 1797w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"860\" height=\"601\" src=\"https:\/\/inspire-polyfoam.de\/wp-content\/uploads\/2021\/11\/Pollex_PCB_02.png\" alt=\"\" class=\"wp-image-1085\" style=\"width:171px;height:119px\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_02.png 860w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_02-300x210.png 300w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_02-768x537.png 768w\" sizes=\"auto, (max-width: 860px) 100vw, 860px\" \/><figcaption class=\"wp-element-caption\">Valor PollEx PCB Verification<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"> <br>PollEx can import designs from different major ECAD vendors, such as Cadence, Mentor Graphics, Zuken and Altium, as well as industrial neutral formats like ODB++ and IPC2581. Using the imported PCB design, PollEx supports verification of design for manufacturability (DFM), design for assembly (DFA), and design for electrical engineering (DFE), along with analyses (SI and thermal). <\/p>\n\n\n\n<h5 class=\"wp-block-heading has-text-align-left\"> <br><strong>Product Highlights<\/strong><\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Product Highlights<\/li>\n\n\n\n<li>Easy-to-use collaborative application to quickly visualize and review PCB designs<\/li>\n\n\n\n<li>Unsurpassed connectivity to major ECAD systems<\/li>\n\n\n\n<li>Powerful rule-based checking tools (DFM, DFA and DFE) to detect faults early in design<\/li>\n\n\n\n<li>Easy solution for SI and thermal analysis of PCBs using the integrated parts and  material libraries <\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading has-text-align-left\"> <br><strong>ECAD Design Review <\/strong><\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Schematic design review from all major  EDA vendors<\/li>\n\n\n\n<li>Gerber (274D, 274X) data review<\/li>\n\n\n\n<li>PCB design review from all major EDA  ECAD vendors<\/li>\n\n\n\n<li>Comparison between PCB-to-PCB and schematic-to-schematic designs<\/li>\n\n\n\n<li>Comparison among PCB, schematic  and BOM<\/li>\n\n\n\n<li>Artwork\/physical\/composition layer view, query, search, and measure for PCB objects<\/li>\n\n\n\n<li>Part, net, pad stack and via library<\/li>\n\n\n\n<li>Save arbitrary design shapes under a different name with a reduced file size,  with a password<\/li>\n\n\n\n<li>Red-Mark (+) feature for comments<\/li>\n\n\n\n<li>Net 2D\/3D display, net topology display and automatic composite net generation <\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"866\" height=\"604\" src=\"https:\/\/inspire-polyfoam.de\/wp-content\/uploads\/2021\/11\/Pollex_PCB_03.png\" alt=\"\" class=\"wp-image-1087\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_03.png 866w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_03-300x209.png 300w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_03-768x536.png 768w\" sizes=\"auto, (max-width: 866px) 100vw, 866px\" \/><figcaption class=\"wp-element-caption\"> <br>Easily and automatically review and compare  PCB designs using PollEx PCB Modeler <\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"866\" height=\"606\" src=\"https:\/\/inspire-polyfoam.de\/wp-content\/uploads\/2021\/11\/Pollex_PCB_04.png\" alt=\"\" class=\"wp-image-1088\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_04.png 866w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_04-300x210.png 300w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_04-768x537.png 768w\" sizes=\"auto, (max-width: 866px) 100vw, 866px\" \/><figcaption class=\"wp-element-caption\"> <br>Analysis of signal integrity and thermal  problems via PollEx Solvers <\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading has-text-align-left\"> <br><strong>Verification &#8211; DFM, DFE and DFA <\/strong><\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Checking items for DFM (500+), DFE (300+), DFA (50+) and DFE+ (50+)<\/li>\n\n\n\n<li>DFM covers the manufacturing areas of board, component, drill, FPCB, package,  pad, pattern, placement, and tooling.<\/li>\n\n\n\n<li>DFE covers the electrical areas of high-speed <br>signals, differential pairs, common nets, power, filters, components, and boards.<\/li>\n\n\n\n<li>DFA covers the manufacturing assembly areas of collision, lead, placement, component and board.<\/li>\n\n\n\n<li>DFE+ provides verification linked to solvers <br>for signal integrity and thermal analysis.<\/li>\n\n\n\n<li>Export customized and formatted Microsoft\u00ae Excel\u00ae reports of verification results.  <\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading has-text-align-left\"><br><strong>Analysis &#8211; Signal Integrity, Thermal  <\/strong><\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li> Built-in material library<\/li>\n\n\n\n<li>Signal integrity:\n<ul class=\"wp-block-list\">\n<li>Transmission line analysis \u2013 TML analysis and trace optimization<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Network analysis \u2013 Waveform analysis,  eye diagram analysis, and network  parameters (RLCG)<\/li>\n\n\n\n<li>Crosstalk analysis<\/li>\n\n\n\n<li>Net topology analysis, including topology editing function<\/li>\n\n\n\n<li>Thermal:\n<ul class=\"wp-block-list\">\n<li>Built-in package-dependent thermal  resistance values for components<\/li>\n\n\n\n<li>3D finite element steady-state analysis <br>results for thermal board contour,  board top\/bottom, and component  junction temperature <\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"660\" src=\"https:\/\/inspire-polyfoam.de\/wp-content\/uploads\/2021\/11\/Pollex_PCB_05-1024x660.png\" alt=\"\" class=\"wp-image-1089\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_05-1024x660.png 1024w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_05-300x193.png 300w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_05-768x495.png 768w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_05.png 1304w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">DDR Design, Thevenin type termination improves impedance mismatch problem<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"651\" src=\"https:\/\/inspire-polyfoam.de\/wp-content\/uploads\/2021\/11\/Pollex_PCB_06-1024x651.png\" alt=\"\" class=\"wp-image-1090\" srcset=\"https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_06-1024x651.png 1024w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_06-300x191.png 300w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_06-768x489.png 768w, https:\/\/ispt-solutions.com\/wp-content\/uploads\/2021\/11\/Pollex_PCB_06.png 1322w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">DDR Design, Decreased Overshoot and opened Eye.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading has-text-align-left\"><br> <strong>Savings in ECAD licenses <\/strong><\/h5>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"> <br> <br>Maximize work efficiency through improved communication among engineers from different disciplines making the same product. PollEx PCB Modeler aids better quality products by sharing schematics, PCBs and Gerber files without the need for expensive ECAD licenses. <\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/inspire-polyfoam.de\/kontakt\/\">Contact us<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.siemens.com\/de-de\/products\/pcb\/valor\/pollex\/?spi=0040038266\" target=\"_blank\" rel=\"noreferrer noopener\">PollEx at Siemens<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<p><!--EndFragment--><\/p>\n<\/p>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Valor PollEx is a PCB-level Electronic Design Automation (EDA) software suite covering design review, analysis and manufacturing. It significantly reduces development cycles while providing a common communication application between schematic engineers, PCB designers, CAE analysts, and manufacturing engineers. PollEx can import designs from different major ECAD vendors, such as Cadence,&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"class_list":["post-1081","page","type-page","status-publish","hentry"],"translation":{"provider":"WPGlobus","version":"3.0.2","language":"en","enabled_languages":["de","en"],"languages":{"de":{"title":true,"content":true,"excerpt":false},"en":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/pages\/1081","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/comments?post=1081"}],"version-history":[{"count":20,"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/pages\/1081\/revisions"}],"predecessor-version":[{"id":1635,"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/pages\/1081\/revisions\/1635"}],"wp:attachment":[{"href":"https:\/\/ispt-solutions.com\/en\/wp-json\/wp\/v2\/media?parent=1081"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}